a
a
Weather:
No weather information available
HomeMeteoForecasting Feels-Like Temperatures: Which Fields to Combine and Why

Forecasting Feels-Like Temperatures: Which Fields to Combine and Why

Forecasting Feels-Like Temperatures: Which Fields to Combine and Why
Forecasting Feels-Like Temperatures: Which Fields to Combine and Why

The WWO API returns at least three different “feels-like” values depending on the endpoint and the conditions: FeelsLikeC, heat index, and wind chill components. Most integrations just grab FeelsLikeC and move on — fine until it isn’t. The failure mode is subtle enough that you won’t catch it in testing, because it only breaks at temperature and humidity extremes.

This post covers what each field actually represents, which one is correct for a given scenario, and how to combine raw API fields yourself when the composite value falls short.

What FeelsLikeC Actually Is

FeelsLikeC (and its Fahrenheit twin FeelsLikeF) is a blended apparent temperature. The underlying logic switches between wind chill and heat index depending on conditions — wind chill dominates when it’s cold and windy, heat index takes over when it’s hot and humid. Most operational weather models apply wind chill below around 10°C and heat index above around 27°C, with a linear interpolation band in between.

That blend is usually what you want for a consumer-facing UI: one number, human-readable, covers most real-world conditions. But if you’re building something that makes decisions — a heat stress alert, a construction site gate, a cold-exposure risk model — you need to know which model is driving the number and whether it’s actually appropriate for your use case.

Wind Chill: The Mechanics

Wind chill quantifies the rate at which exposed skin loses heat to the environment. The formula most widely used today was revised by the US National Weather Service and the Meteorological Service of Canada in 2001, replacing an older Siple-Passel formula that consistently read too cold in calm-wind conditions.

The revised formula:

WC = 13.12 + 0.6215T − 11.37V^0.16 + 0.3965T × V^0.16

Where T is air temperature in °C and V is wind speed in km/h. The raw inputs you need from the API are temp_C and windspeedKmph — both available in current_condition and in the hourly arrays under weather.

Wind chill is only physically meaningful at or below 10°C and above 4.8 km/h wind speed. Apply it to a 20°C calm day and you get a number, but that number doesn’t correspond to anything real. The model assumes dry, bare skin in a standardized walking-pace scenario, so it overstates cooling for someone sitting still in a shelter and can understate it for someone wet or at altitude.

Heat Index: The Mechanics

Heat index — sometimes called the Steadman apparent temperature — models the combined effect of air temperature and relative humidity on how hot the body feels. The body cools itself primarily through sweat evaporation; high humidity suppresses that evaporation, so the same air temperature reads much hotter when it’s muggy.

The NWS Rothfusz regression is the standard formulation:

HI = -42.379 + 2.04901523T + 10.14333127R
     − 0.22475541TR − 0.00683783T² − 0.05481717R²
     + 0.00122874T²R + 0.00085282TR² − 0.00000199T²R²

Where T is temperature in °F and R is relative humidity as a percentage. From the WWO API you need temp_F and humidity.

Validity range matters. The Rothfusz regression is most accurate above 80°F (26.7°C) and above 40% relative humidity. Below those thresholds the formula can produce results cooler than actual air temperature, which is physically nonsensical. The NWS applies two adjustment equations for low-humidity or high-humidity extremes — worth implementing if you’re surfacing this for tropical climates or desert conditions.

A minimal Python function that handles the basic range check:

def heat_index_f(temp_f: float, rh: float) -> float | None:
    """Returns heat index in °F, or None if conditions are outside valid range."""
    if temp_f < 80 or rh < 40:
        return None  # not meaningful; return air temp instead

    hi = (
        -42.379
        + 2.04901523 * temp_f
        + 10.14333127 * rh
        - 0.22475541 * temp_f * rh
        - 0.00683783 * temp_f ** 2
        - 0.05481717 * rh ** 2
        + 0.00122874 * temp_f ** 2 * rh
        + 0.00085282 * temp_f * rh ** 2
        - 0.00000199 * temp_f ** 2 * rh ** 2
    )
    return hi

Returning None outside the valid range is deliberate — it forces the caller to decide what to show rather than silently displaying a misleading number.

When FeelsLikeC Gets It Wrong

Three scenarios where the blended composite isn’t what you want:

1. Heat stress thresholds for health or occupational use

OSHA’s heat illness guidance and NIOSH criteria are built around Wet Bulb Globe Temperature (WBGT), not heat index. Heat index is a reasonable proxy in shade with low solar load, but in direct sun — a construction site, an agricultural field, a port — WBGT can run 5–8°C higher than the shade heat index. The WWO API doesn’t return WBGT directly, but you can approximate it from temp_C, humidity, and uvIndex using the simplified Bernard-Pourmoghani equation if you need a rough outdoor WBGT without a physical instrument.

2. Cold extremes with high wind

At temperatures below −20°C with winds above 50 km/h, the difference between FeelsLikeC and a correctly-computed wind chill can be several degrees — enough to shift a recommendation from “caution” to “frostbite risk within 10 minutes.” If you’re building anything for Arctic logistics, ski resort operations, or cold-chain delivery routing, recalculate wind chill directly from the raw fields rather than trusting the composite.

3. Transitional conditions near the crossover band

At roughly 10–27°C, neither wind chill nor heat index is dominant. FeelsLikeC in this range reflects the weighted blend, which can produce output slightly lower than air temperature on a mild, calm day. That’s usually fine for display, but if you’re running a threshold alert at exactly 15°C — say, triggering a “jacket weather” notification — a sub-degree underestimate from the blend can flip the alert either way. Test this range explicitly if threshold-crossing matters in your product.

Pulling the Right Fields From the API

For current conditions, all the inputs you need are in current_condition[0]:

  • temp_C / temp_F — air temperature
  • FeelsLikeC / FeelsLikeF — blended apparent temperature
  • humidity — relative humidity, percent
  • windspeedKmph / windspeedMiles — 10-metre wind speed
  • uvIndex — useful for solar load estimation if you’re approximating WBGT

For hourly forecast data, the same fields appear inside each object in the hourly array. One thing to watch: hourly arrays use tempC (no underscore) rather than temp_C. That inconsistency exists across the API and it’s the kind of thing that bites you when you’re porting code written for the current-conditions endpoint to the forecast endpoint. Build a small normalization layer early.

A Practical Decision Tree

When deciding which value to surface or compute:

  • Consumer display, general UI: Use FeelsLikeC. It’s correct enough for the vast majority of conditions and you don’t need to maintain formula logic.
  • Cold-weather alerts, winter logistics, ski/mountain: Recompute wind chill from temp_C + windspeedKmph when temp is below 10°C and wind is above 5 km/h. Store the formula version alongside FeelsLikeC so you can diff them and catch edge cases.
  • Heat stress alerts, tropical maritime, construction/agriculture: Recompute heat index from temp_F + humidity. Return None outside the valid range and fall back to air temperature. Add a solar load correction if the use case involves direct sun exposure.
  • Occupational health, OSHA-adjacent: Approximate WBGT or use heat index with explicit documentation of the limitation. Don’t present either as equivalent to a measured WBGT — they’re not.

A Caveat Worth Stating Plainly

All of these models — wind chill, heat index, apparent temperature — are empirical approximations developed under specific experimental conditions. Wind chill was calibrated on adult volunteers walking at 1.34 m/s in a wind tunnel. Heat index assumes a 5’7″, 147-pound adult in shade. Real human thermal comfort depends on clothing, body fat, fitness, acclimatization state, and metabolic rate in ways these formulas can’t capture. They’re useful for population-level guidance. They’re not precise enough to substitute for professional occupational health assessment when individual risk matters.

That’s not a reason to avoid them — it’s a reason to be clear in your UI copy about what the number means. “Feels like 38°C” should read as “conditions equivalent to 38°C still air,” not as a precise physiological prediction.

If you’re surfacing heat stress risk in a production system, show both the raw temperature and the computed apparent value, let users see the gap, and document which formula you used. That transparency is worth more than a tidier UI — and if something goes wrong, you’ll want the paper trail showing you didn’t just trust the composite blindly.

The post Forecasting Feels-Like Temperatures: Which Fields to Combine and Why appeared first on Weather Blog.